Technical Document
Specifications
Brand
Allen BradleySupply Voltage
24V ac/dc
Number of Channels
2
Safety Contacts
3
Function
Safety Monitoring
Auxiliary Contacts
1
Reset Method
Automatic & Manual
Range
Guardmaster MSR, Minotaur
Safety Category ISO 13849-1
4
Safety Category (ISO 13849-1)
4
PL ISO 13849-1
e
PL (ISO 13849-1)
e
SIL IEC 61508
3
SIL (IEC 61508)
3
Terminal Type
Screw
Series
440R / MSR127T
Width
99mm
Depth
22.5mm
Performance Level
e
Length
114.5mm
Country of Origin
Czech Republic
Product details
Rockwell Automation 440R Minotaur MSR127RTP Safety Relay, Single Channel
For dependable fault detection that will minimise downtime and help you keep operations running efficiently, the 440R Minotaur MSR127RTP Single Function Safety Relays by Rockwell Automation are the ideal choice for your safety control system. The MSR family of relays are perfectly suited for relatively small safety applications and single zone control.
These versatile single function safety relays can be connected in 3 different input wiring configurations: 1NC, 2NC, or with two PNP connections from a light curtain. The MSR127RT checks for cross faults across the two inputs when connected in the 2NC configuration. The light curtain must perform the cross fault detection when the safety relay is connected to light curtains.
The MSR127TP relay features an automatic/manual reset, which can be jumpered or changed to an unmonitored manual reset by the addition of a normally open switch in the monitoring loop. The MSR127RP unit has a monitored manual reset which offers checking of the output monitoring circuit.
These devices are ideal for light curtain, E-stop or safety gate applications.
Features and Benefits:
Compact housing
Stop category 0 and Cross fault monitoring
Cat. 4 per EN954-1
Relays with monitored or automatic reset
Removable terminals
Three NO (Normally Open) safety-rated outputs, one NC (Normally Closed) auxiliary contact
Safety outputs feature independent and redundant internal contacts to support the safety function
Auxiliary output is a non-safety output which can provide an external signal to indicate the status of the safety outputs
Standards:
EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-4-1, IEC 60947-5-1, ANSI B11.19, AS4024.1.
Stock information temporarily unavailable.
Please check again later.
BD 74.025
Each (Exc. Vat)
BD 81.427
Each (inc. VAT)
1
BD 74.025
Each (Exc. Vat)
BD 81.427
Each (inc. VAT)
1
Technical Document
Specifications
Brand
Allen BradleySupply Voltage
24V ac/dc
Number of Channels
2
Safety Contacts
3
Function
Safety Monitoring
Auxiliary Contacts
1
Reset Method
Automatic & Manual
Range
Guardmaster MSR, Minotaur
Safety Category ISO 13849-1
4
Safety Category (ISO 13849-1)
4
PL ISO 13849-1
e
PL (ISO 13849-1)
e
SIL IEC 61508
3
SIL (IEC 61508)
3
Terminal Type
Screw
Series
440R / MSR127T
Width
99mm
Depth
22.5mm
Performance Level
e
Length
114.5mm
Country of Origin
Czech Republic
Product details
Rockwell Automation 440R Minotaur MSR127RTP Safety Relay, Single Channel
For dependable fault detection that will minimise downtime and help you keep operations running efficiently, the 440R Minotaur MSR127RTP Single Function Safety Relays by Rockwell Automation are the ideal choice for your safety control system. The MSR family of relays are perfectly suited for relatively small safety applications and single zone control.
These versatile single function safety relays can be connected in 3 different input wiring configurations: 1NC, 2NC, or with two PNP connections from a light curtain. The MSR127RT checks for cross faults across the two inputs when connected in the 2NC configuration. The light curtain must perform the cross fault detection when the safety relay is connected to light curtains.
The MSR127TP relay features an automatic/manual reset, which can be jumpered or changed to an unmonitored manual reset by the addition of a normally open switch in the monitoring loop. The MSR127RP unit has a monitored manual reset which offers checking of the output monitoring circuit.
These devices are ideal for light curtain, E-stop or safety gate applications.
Features and Benefits:
Compact housing
Stop category 0 and Cross fault monitoring
Cat. 4 per EN954-1
Relays with monitored or automatic reset
Removable terminals
Three NO (Normally Open) safety-rated outputs, one NC (Normally Closed) auxiliary contact
Safety outputs feature independent and redundant internal contacts to support the safety function
Auxiliary output is a non-safety output which can provide an external signal to indicate the status of the safety outputs
Standards:
EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-4-1, IEC 60947-5-1, ANSI B11.19, AS4024.1.