Technical Document
Specifications
Brand
BartecProduct Type
Limit Switch
Actuator Type
Plunger
IP Rating
IP54
Contact Configuration
SPDT
Housing Material
Duroplast
Contact Type
Snap Action
Terminal Type
Screw
Switching Current
5A
Minimum Operating Temperature
-40°C
Switching DC Voltage
250V dc
Switching AC Voltage
250V ac
Maximum Operating Temperature
90°C
Depth
10mm
Length
29.8mm
Standards/Approvals
RoHS
Width
18mm
Hazardous Area Certification
ATEX
Conduit Entry
20 mm
Mechanical Life
10000000Cycles
Operating Force
1.2N
Mounting Orientation
Side
Country of Origin
Germany
Product details
Bartec Miniature Limit Switch / Insert Switch
EExd miniature switches for use in areas where a flameproof switching element is required. Two types of switches are available to suit different equipment construction requirements, Limit Switches and Insert Switches. The Limit Switch type requires mechanical protection for the switch body and cable, no further testing is required. The Insert Switch is to be installed in a enclosure that provides mechanical protection and which fulfils the requirements of EN 50014 section 1.2 .
IP54 protection rating
Silver changeover contacts
250Vac 5A (resistive), 250Vdc 0.25A (resistive), 30Vdc 5A (resistive)
107 operations
Body width 18mm, height 28mm, depth 10mm
Long lever actuator length 65mm, Short lever 14mm
Limit Switch cable length 1m, Insert Switch leads length 500mm
Potted cable / leads to switch base
Stock information temporarily unavailable.
BD 92.607
BD 92.607 Each (Exc. Vat)
BD 101.868
BD 101.868 Each (inc. VAT)
1
BD 92.607
BD 92.607 Each (Exc. Vat)
BD 101.868
BD 101.868 Each (inc. VAT)
Stock information temporarily unavailable.
1
| Quantity | Unit price |
|---|---|
| 1 - 4 | BD 92.607 |
| 5 - 9 | BD 89.746 |
| 10+ | BD 85.937 |
Technical Document
Specifications
Brand
BartecProduct Type
Limit Switch
Actuator Type
Plunger
IP Rating
IP54
Contact Configuration
SPDT
Housing Material
Duroplast
Contact Type
Snap Action
Terminal Type
Screw
Switching Current
5A
Minimum Operating Temperature
-40°C
Switching DC Voltage
250V dc
Switching AC Voltage
250V ac
Maximum Operating Temperature
90°C
Depth
10mm
Length
29.8mm
Standards/Approvals
RoHS
Width
18mm
Hazardous Area Certification
ATEX
Conduit Entry
20 mm
Mechanical Life
10000000Cycles
Operating Force
1.2N
Mounting Orientation
Side
Country of Origin
Germany
Product details
Bartec Miniature Limit Switch / Insert Switch
EExd miniature switches for use in areas where a flameproof switching element is required. Two types of switches are available to suit different equipment construction requirements, Limit Switches and Insert Switches. The Limit Switch type requires mechanical protection for the switch body and cable, no further testing is required. The Insert Switch is to be installed in a enclosure that provides mechanical protection and which fulfils the requirements of EN 50014 section 1.2 .
IP54 protection rating
Silver changeover contacts
250Vac 5A (resistive), 250Vdc 0.25A (resistive), 30Vdc 5A (resistive)
107 operations
Body width 18mm, height 28mm, depth 10mm
Long lever actuator length 65mm, Short lever 14mm
Limit Switch cable length 1m, Insert Switch leads length 500mm
Potted cable / leads to switch base