Technical Document

Specifications

Number of Channels

3

Module Type

Zener Barrier

Barrier Type

Zener Barrier

Maximum Voltage

250V

Hazardous Area Certification

ATEX

Safety Current Resistance

27.27Ω

Supply Voltage

250V ac

Maximum Current

383mA

Minimum Operating Temperature

-20°C

Maximum Operating Temperature

+60°C

Safety Current Maximum

383mA

Safety Voltage Maximum

250 V

Operating Temperature Range

-20 → +60°C

Product details

Z954 Triple Channel

The above drawing shows a RTD temperature sensor in a 3-wire design that relay the measured temperature through a 4.5V 12Ω triple channel zener barrier. The entire system is quasi-floating. All three channels have an identical end to end resistance.Typical application - RTD temperature measuring devices

Isolation Barriers

Pepperl+Fuchs shunt zener diode barriers are for use as safety interfaces between intrinsically safe and non-intrinsically safe circuits. They are manufactured from Makrolon® and designed to conduct electrical signals - in either direction - between safe and hazardous areas and to limit the amount of energy which can be transferred from a safe to a hazardous area in the event of fault conditions occurring in the safe area. All systems shown are licensed for [EEx ia] IIC Class 1, Div1, Groups A-G

You may be interested in

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

BD 80.850

Each (Exc. Vat)

BD 88.935

Each (inc. VAT)

Pepperl + Fuchs 3 Channel Zener Barrier, ATEX

BD 80.850

Each (Exc. Vat)

BD 88.935

Each (inc. VAT)

Pepperl + Fuchs 3 Channel Zener Barrier, ATEX
Stock information temporarily unavailable.
You may be interested in

Technical Document

Specifications

Number of Channels

3

Module Type

Zener Barrier

Barrier Type

Zener Barrier

Maximum Voltage

250V

Hazardous Area Certification

ATEX

Safety Current Resistance

27.27Ω

Supply Voltage

250V ac

Maximum Current

383mA

Minimum Operating Temperature

-20°C

Maximum Operating Temperature

+60°C

Safety Current Maximum

383mA

Safety Voltage Maximum

250 V

Operating Temperature Range

-20 → +60°C

Product details

Z954 Triple Channel

The above drawing shows a RTD temperature sensor in a 3-wire design that relay the measured temperature through a 4.5V 12Ω triple channel zener barrier. The entire system is quasi-floating. All three channels have an identical end to end resistance.Typical application - RTD temperature measuring devices

Isolation Barriers

Pepperl+Fuchs shunt zener diode barriers are for use as safety interfaces between intrinsically safe and non-intrinsically safe circuits. They are manufactured from Makrolon® and designed to conduct electrical signals - in either direction - between safe and hazardous areas and to limit the amount of energy which can be transferred from a safe to a hazardous area in the event of fault conditions occurring in the safe area. All systems shown are licensed for [EEx ia] IIC Class 1, Div1, Groups A-G