P.M.A KS92 PID Temperature Controller, 96 x 96 (1/4 DIN)mm, 4 Output Relay, 18 → 30 V dc, 24 V ac Supply Voltage
Technical Document
Specifications
Brand
P.M.AOutput Type
Relay
Supply Voltage
18 → 30 V dc, 24 V ac
Size
96 x 96 (1/4 DIN)mm
Number of Outputs
4
Minimum Operating Temperature
0°C
Maximum Operating Temperature
+60°C
Temperature Range
0 → +1760 (Type R Thermocouple - PtRh-Pt) °C, 0 → +1760 (Type S Thermocouple - PtRh-Pt) °C, 0 → +1820 (Type B Thermocouple - PtRh-Pt6) °C, -100 → +1000 (Type E Thermocouple - NiCr-CuNi) °C, -100 → +1200 (Type J Thermocouple - Fe-CuNi) °C, -100 → +1300 (Type N Thermocouple - Nicrosil/Nisil) °C, -100 → +1350 (Type K Thermocouple - NiCr-Ni) °C, -100 → +900 (Type L Thermocouple - Fe-CuNi) °C, -200 → +200 (PT1000) °C, -200 → +400 (Type T Thermocouple - Cu-CuNi) °C
Control Type
ON/OFF
Display Type
LED, Multi Line
IP Rating
IP00, IP20, IP65
Range
PMA KS92-1
Series
KS92
Additional Functionality
ON/OFF
Panel Depth
118mm
Display Colour
Red
Country of Origin
United Kingdom
Product details
PMA KS 92-1 Temperature Controller
The KS 92-1 process controller is suitable for universal, precise, and cost-effective control. The instrument provides simple 2-point (on/off) control, continuous PID control, or 3-point stepping control.
The process value signal is connected via a universal input. A supplementary analogue input can be used for heating current measurement, as an external set-point inputter for position feedback measurement of motorised stepping controllers.
The optional 3rd input is a universal input that can be used for several functions, e.g. temperature dependent setpoint correction or differential control. The standard KS 92-1 is suitable for oxygen control using heated and unheated O2 sensors.
The KS 92-1 is particularly suited to the following applications: Furnaces and ovens, Burners and boilers, Plastics processing & Driers.
• BluePort®
• Front interface and BlueControl software
• Maintenance manager and error list
• Two universal inputs
• Day & Night display shows plain text and bargraphs
• Manual gain scheduling
• Self-Tuning to the setpoint without oscillation
• Valve controller with position feedback and DAC monitoring
• 3-point controller for water, fan and oil cooling
• Type tested to EN 14597 (replaces DIN 3440) and cULus
• High-impedance mV input for O2 sensors
PMA Temperature Controllers
BD 337.696
BD 337.696 Each (Exc. Vat)
BD 371.466
BD 371.466 Each (inc. VAT)
1
BD 337.696
BD 337.696 Each (Exc. Vat)
BD 371.466
BD 371.466 Each (inc. VAT)
1
Stock information temporarily unavailable.
Please check again later.
Technical Document
Specifications
Brand
P.M.AOutput Type
Relay
Supply Voltage
18 → 30 V dc, 24 V ac
Size
96 x 96 (1/4 DIN)mm
Number of Outputs
4
Minimum Operating Temperature
0°C
Maximum Operating Temperature
+60°C
Temperature Range
0 → +1760 (Type R Thermocouple - PtRh-Pt) °C, 0 → +1760 (Type S Thermocouple - PtRh-Pt) °C, 0 → +1820 (Type B Thermocouple - PtRh-Pt6) °C, -100 → +1000 (Type E Thermocouple - NiCr-CuNi) °C, -100 → +1200 (Type J Thermocouple - Fe-CuNi) °C, -100 → +1300 (Type N Thermocouple - Nicrosil/Nisil) °C, -100 → +1350 (Type K Thermocouple - NiCr-Ni) °C, -100 → +900 (Type L Thermocouple - Fe-CuNi) °C, -200 → +200 (PT1000) °C, -200 → +400 (Type T Thermocouple - Cu-CuNi) °C
Control Type
ON/OFF
Display Type
LED, Multi Line
IP Rating
IP00, IP20, IP65
Range
PMA KS92-1
Series
KS92
Additional Functionality
ON/OFF
Panel Depth
118mm
Display Colour
Red
Country of Origin
United Kingdom
Product details
PMA KS 92-1 Temperature Controller
The KS 92-1 process controller is suitable for universal, precise, and cost-effective control. The instrument provides simple 2-point (on/off) control, continuous PID control, or 3-point stepping control.
The process value signal is connected via a universal input. A supplementary analogue input can be used for heating current measurement, as an external set-point inputter for position feedback measurement of motorised stepping controllers.
The optional 3rd input is a universal input that can be used for several functions, e.g. temperature dependent setpoint correction or differential control. The standard KS 92-1 is suitable for oxygen control using heated and unheated O2 sensors.
The KS 92-1 is particularly suited to the following applications: Furnaces and ovens, Burners and boilers, Plastics processing & Driers.
• BluePort®
• Front interface and BlueControl software
• Maintenance manager and error list
• Two universal inputs
• Day & Night display shows plain text and bargraphs
• Manual gain scheduling
• Self-Tuning to the setpoint without oscillation
• Valve controller with position feedback and DAC monitoring
• 3-point controller for water, fan and oil cooling
• Type tested to EN 14597 (replaces DIN 3440) and cULus
• High-impedance mV input for O2 sensors