Technical Document
Specifications
Brand
Chauvin ArnouxAbsolute Maximum Current Measurement
6500A
Maximum Voltage
1000V
Display Type
LCD
Measurement Type
Current, Energy, Frequency, Harmonics, Inrush Current, Power Factor, Voltage
Interface Type
RS232, USB
Power Source
Battery
Battery Type
Rechargeable NiMH
Model Number p
CA 8335
Dimensions
24 x 180 x 55mm
Weight
1.9kg
Height
55mm
Width
180mm
Length
24mm
Maximum Frequency
69Hz
Minimum Frequency
40 Hz
Country of Origin
France
Product details
CA8335 QualiSTAR three-phase energy network analyser
Measurement of all voltage, current and power values needed for a full diagnostic check of an electrical system.
Simultaneous detection and recording of all parameters, transients, alarms and waveforms.
Real-time display of wave forms (4 voltages and 4 currents).
Half-period measurements of voltages and currents.
User-friendly.
Automatic recognition of the different types of current sensors.
Analysis of all continuous components..
Measurement, calculation and display of harmonics to the 50th order, including phase information.
Calculation of total harmonic distortion (THD).
Capture of transients through sampling (1/256th of a period).
Display of phase diagrams.
Measurement of total VA, W and var power values and values by phase.
Measurement of total VAh, Wh and varh energy values and values by phase.
Calculation of the K factor.
Calculation of the cos φ displacement power factor (DPF) and the power factor (PF).
Captures up to 300 transients.
Flicker calculation.
Calculation of current and voltage imbalance.
Monitoring of the electrical network and alarm setting.
Back-up and recording of screenshots (images and data).
Software for data recovery and real-time communication with a PC.
Recording and export to PC.
Supplied with
1 bag no. 22, 1 USB cable, 1 power charger, 1 mains lead, 5 voltage leads (length = 3 m) with 4-mm banana plugs, 5 crocodile clips, 1 12-colour identification set for leads and inputs, 1 protective screen film, 1 safety plug, multilingual user guide, 1 PC data recovery software program.
Standards
IEC 61010 1000 V CAT III / 600 V CAT IV
Stock information temporarily unavailable.
Please check again later.
P.O.A.
1
P.O.A.
1
Technical Document
Specifications
Brand
Chauvin ArnouxAbsolute Maximum Current Measurement
6500A
Maximum Voltage
1000V
Display Type
LCD
Measurement Type
Current, Energy, Frequency, Harmonics, Inrush Current, Power Factor, Voltage
Interface Type
RS232, USB
Power Source
Battery
Battery Type
Rechargeable NiMH
Model Number p
CA 8335
Dimensions
24 x 180 x 55mm
Weight
1.9kg
Height
55mm
Width
180mm
Length
24mm
Maximum Frequency
69Hz
Minimum Frequency
40 Hz
Country of Origin
France
Product details
CA8335 QualiSTAR three-phase energy network analyser
Measurement of all voltage, current and power values needed for a full diagnostic check of an electrical system.
Simultaneous detection and recording of all parameters, transients, alarms and waveforms.
Real-time display of wave forms (4 voltages and 4 currents).
Half-period measurements of voltages and currents.
User-friendly.
Automatic recognition of the different types of current sensors.
Analysis of all continuous components..
Measurement, calculation and display of harmonics to the 50th order, including phase information.
Calculation of total harmonic distortion (THD).
Capture of transients through sampling (1/256th of a period).
Display of phase diagrams.
Measurement of total VA, W and var power values and values by phase.
Measurement of total VAh, Wh and varh energy values and values by phase.
Calculation of the K factor.
Calculation of the cos φ displacement power factor (DPF) and the power factor (PF).
Captures up to 300 transients.
Flicker calculation.
Calculation of current and voltage imbalance.
Monitoring of the electrical network and alarm setting.
Back-up and recording of screenshots (images and data).
Software for data recovery and real-time communication with a PC.
Recording and export to PC.
Supplied with
1 bag no. 22, 1 USB cable, 1 power charger, 1 mains lead, 5 voltage leads (length = 3 m) with 4-mm banana plugs, 5 crocodile clips, 1 12-colour identification set for leads and inputs, 1 protective screen film, 1 safety plug, multilingual user guide, 1 PC data recovery software program.
Standards
IEC 61010 1000 V CAT III / 600 V CAT IV